conventions
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
conventions [2020/11/03 19:53] – [Layer name] mcmaster | conventions [2025/01/22 05:35] (current) – [Objective] bunnie | ||
---|---|---|---|
Line 33: | Line 33: | ||
* st_24c02_mz_ns50xu.jpg: | * st_24c02_mz_ns50xu.jpg: | ||
* st_24c02_mz.jpg: | * st_24c02_mz.jpg: | ||
+ | * Complex example | ||
+ | * ti_tms32010c-70015_s1-2_mit20x_rom.jpg | ||
+ | * Vendor: Texas Instruments (ti) | ||
+ | * Chip: TMS32010C | ||
+ | * Chip variant: 70015 (in this case the ROM programming) | ||
+ | * s1-2: sample 1, processing step 2. Please list processing steps on wiki page if available | ||
+ | * mit20x: objective used | ||
+ | * rom: a region of interest within the 20x scan | ||
* wafer example | * wafer example | ||
- | * mos_8564r6-wafer_mz.jpg: a MOS 8564R6 wafer top metal. Main chip | + | * mos_8564r6-wafer_mz_die.jpg: a MOS 8564R6 wafer top metal. Main chip |
- | * mos_8564r6-wafer_mz-9079r2_mz.jpg: a MOS 8564R6 wafer top metal, but the test pattern 9079R2 | + | * mos_8564r6-wafer_mz_9079r2.jpg: a MOS 8564R6 wafer top metal, but the test pattern 9079R2 |
===== Technique ===== | ===== Technique ===== | ||
Line 69: | Line 77: | ||
* am100x: AmScope 100x (oil immersion) | * am100x: AmScope 100x (oil immersion) | ||
* bli20x: Bausch & Lomb industrial 20x (designed for stereozoom series) | * bli20x: Bausch & Lomb industrial 20x (designed for stereozoom series) | ||
+ | * boli10xir: Boli Optics M Plan Apo 10x NIR (comparable to Mitsutoyo) | ||
* ch2x: cheap supposedly Apo 2x objective that may be made of soda glass (green tinge…). | * ch2x: cheap supposedly Apo 2x objective that may be made of soda glass (green tinge…). | ||
* mit5x: Mitutoyo M Plan Apo 5x | * mit5x: Mitutoyo M Plan Apo 5x | ||
Line 75: | Line 84: | ||
* mit50xn: Mitutoyo M Plan Apo 50x Near UV | * mit50xn: Mitutoyo M Plan Apo 50x Near UV | ||
* mit100x: Mitutoyo M Plan Apo 100x | * mit100x: Mitutoyo M Plan Apo 100x | ||
+ | * nikon20x: Nikon M Plan 20x ELWD | ||
* neo5x: Olympus Neo 5x | * neo5x: Olympus Neo 5x | ||
* nd5x: Olympus Neo DPlan 5x | * nd5x: Olympus Neo DPlan 5x | ||
* ns50x: Olympus Neo SPlan 50x | * ns50x: Olympus Neo SPlan 50x | ||
* ns50xu: Olympus Neo SPlan 50x ultra-long working distance (ULWD) | * ns50xu: Olympus Neo SPlan 50x ultra-long working distance (ULWD) | ||
+ | * md5x: Olympus MDPlan 5x | ||
+ | * ms10x: Olympus MSPlan 10x | ||
+ | * ms20x: Olympus MSPlan 20x | ||
+ | * ms50x: Olympus MSPlan 50x | ||
+ | * ms100x: Olympus MSPlan 100x | ||
+ | * opl100x: Olympus Plan 100x Oil 1.25NA | ||
+ | * oplcn100x: Olympus Plan CN 100x Oil 1.25NA | ||
* sz or zoom: Zoom microscope, generally no scale bar provided because magnification varies (unless that particular zoom setting was calibrated during the same imaging session) | * sz or zoom: Zoom microscope, generally no scale bar provided because magnification varies (unless that particular zoom setting was calibrated during the same imaging session) | ||
- | |||
- | Scales | ||
- | |||
- | ^ Scope ^ Objective | ||
- | | pr0nscope | ||
- | | pr0nscope | ||
- | | pr0nscope | ||
- | | pr0nscope | ||
- | | pr0nscope | ||
- | | pr0nscope | ||
- | | pr0nscope | ||
- | | pr0nscope | ||
See also | See also |