Table of Contents

mcmaster equipment notes. Both broken when I got them

TEC misc

Failure modes?

Can they fail open? Maybe not (assuming the wires are good). I think all of the elements are in parallel

https://electronics.stackexchange.com/questions/261655/what-happens-when-a-peltier-fails

Firstly, it appears that peltiers often slowly decline according to the referenced article, with increased resistance and decreased heat pump capacity.

Therefore, my proposition is that in a typical heating application the heat produced by a perfeclty-shorted 100W peltier would be the equivalent of a 50W, poorly back-insulted, resistance element.

Oasis 150

Power supply: roughly 12V @ 8A.

TODO:

Thermotek T251P-2

AKA: Silicon Thermal Powercool CH250

something like 28V @ 5A

10 TECs in series

Measured one TEC: 4V @ 1.4A start voltage

TODO:

mcmaster

TEC:

marlow
industries, inc.
(/P)

DT12-6 L

47348

USA
- +

I found DT12-4 and DT12-8 datasheets. Looks like linear relationship. Interpolated datasheet:

Thread

Reference: https://photonlexicon.com/forums/showthread.php/6533-Thermotek-Chillers-Exposed!-(TEC-Question)