bonding:ks4522
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
bonding:ks4522 [2015/12/11 19:21] – [Process development / troubleshooting] azonenberg | bonding:ks4522 [2019/03/04 23:35] (current) – removed mcmaster | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | This article describes the care and feeding of the K&S 4522 semi-automatic ball bonder. | ||
- | ====== Gross Anatomy ====== | ||
- | |||
- | The figures below show the major components of the bonder. | ||
- | |||
- | {{: | ||
- | |||
- | {{: | ||
- | |||
- | ====== Startup ====== | ||
- | |||
- | Turn on the power switch. The " | ||
- | |||
- | The standard control configurations are as follows. These are not ideal for every application but are a good start for process development. Note that these parameters are in arbitrary units and target values for the same process may vary slightly between individual machines. These parameters were developed for the specific unit pictured by AZ and a service technician for the bonder during training. | ||
- | |||
- | Search height is only used for semi-auto mode and is not used in manual-Z mode. | ||
- | |||
- | Left control panel | ||
- | |||
- | * Clamp closed (down) | ||
- | * Light on (up) | ||
- | * Loop 3.1 | ||
- | * Tail 4.4 | ||
- | * 1st bond | ||
- | * Search 221 | ||
- | * Power 251 | ||
- | * Time 3.2 | ||
- | * Force 6.1 | ||
- | * 2nd bond | ||
- | * Search 236 | ||
- | * Power 300 | ||
- | * Time 4 | ||
- | * Force 7.0 | ||
- | |||
- | {{: | ||
- | |||
- | Right control panel: | ||
- | |||
- | * Ball size 371 | ||
- | * Chuck temp 54C | ||
- | * Setup/reset in middle (normal) position | ||
- | * NEFO (HV power supply for ball formation) on | ||
- | * Motor on | ||
- | * Mode switch in " | ||
- | |||
- | {{: | ||
- | |||
- | Tool lift lever (left and behind of bond head) should be pushed all the way down | ||
- | |||
- | Place the chuck/work holder assembly on top of the stage, being careful not to hit the capillary with the sample or chuck. Adjust chuck height as necessary. FIXME: What is typical clearance from resting capillary tip to bond surface? Need to measure. In semi-auto mode, the search height should be adjusted so that it is 75-125 um above the bond pad or leadframe. | ||
- | |||
- | ====== Shutdown ====== | ||
- | |||
- | Remove work holder from under capillary to reduce the risk of breaking the capillary if the machine is bumped. | ||
- | |||
- | Turn off the power switch and put the dust cover over the system. | ||
- | |||
- | ====== Basic operation ====== | ||
- | |||
- | //NOTE: This section only describes manual-Z mode. The semiautomatic mode may be better for high volume but in a prototype it's easier to do it by hand than configure the semiauto height adjustment. // | ||
- | |||
- | - Turn on the machine and re-thread the wire if necessary. | ||
- | - Mount the sample on the chuck. DIP-style packages can be put over the aluminum jigs and held in place by the clamp. SMT packages are typically attached with double sided Kapton tape. \\ {{: | ||
- | - Adjust settings as necessary. Changes to the bond force will only take effect when the " | ||
- | - To make the first bond: | ||
- | * Use the mouse to position the capillary near the bond pad and push slowly in on the mouse thumb button to lower the capillary until it's just above the pad. Putting the midpoint of the capillary and its reflection on the bond pad usually gives good alignment. (FIXME: Get a photo of this). The projected crosshair can be used for alignment (once calibrated using the X and Y axis knobs on the crosshair projector) but in AZ's experience this is only viable for the second bond; the crosshair is typically difficult to see on highly reflective die surfaces. | ||
- | * After the capillary is aligned, press the left mouse button to make the first (ball) bond. | ||
- | * If the bond does not stick to the die, the ball will be damaged and cannot be re-used. Move the capillary over a leadframe bond pad or the carrier island and click the left mouse button to bond off the damaged ball and prepare a new ball. | ||
- | - To make the second bond: | ||
- | * Align the capillary over the pad on the leadframe, lower to check position, and click the left button to make the second bond. After the bond is complete the capillary will lift up and the NEFO wand will move in and strike an arc to the wire to form a new ball. | ||
- | |||
- | ====== Process development / troubleshooting ====== | ||
- | |||
- | FIXME: Expand this section | ||
- | |||
- | * Bond ball should be ~2x wire diameter. If too squished, reduce power, pressure, or time (in that order) | ||
- | * If loops sag, increase tension on glass plate | ||
- | * If wire snaps when trying to feed the loop, reduce clamp tension | ||
- | * If clamp doesn' | ||
- | * Drag plate tension should be just enough to remove slack | ||
- | * If second bond does not have visible ring (as seen below), increase power. \\ {{: | ||
- | * If mouse sticks, rub a small amount of wax into the black mat area under the mouse | ||
- | * If temperature reads " | ||
- | * To remove excess wire, or if the spark didn't strike, push the solenoid for the NEFO wand in until it is ~0.5mm from the wire then push the " | ||
- | * If wire consistently breaks after a bond, use less power (?) | ||
- | |||
- | ====== Bond force calibration ====== | ||
- | |||
- | * Put mode in semiauto | ||
- | * Go to setup | ||
- | * Click and hold left mouse button | ||
- | * Push up on transducer arm just behind capillary with spring scale and measure force | ||
- | |||
- | Target force range for typical process is 40-60 gf | ||
- | |||
- | ====== Maintenance ====== | ||
- | |||
- | |||
- | ===== Capillary replacement and height adjustment ===== | ||
- | |||
- | Place a soft material over the stage plate to protect the capillary if it drops. ESD foam is commonly available and does the job just fine. | ||
- | |||
- | Loosen the setscrew and remove the old capillary, if any. Insert the new capillary from the bottom and position it such that about one capillary diameter sticks out of the top of the transducer arm, then tighten the setscrew. Handle the capillary with tweezers or gloves to avoid getting finger oils on it. | ||
- | |||
- | {{: | ||
- | |||
- | To calibrate the capillary position place the height gauge below and behind it, loosen the setscrew, and lift until the tip of the gauge hits the transducer arm, then tighten. | ||
- | |||
- | {{: | ||
- | |||
- | To check the capillary installation push the test switch (left control panel) down briefly. The ultrasound (" | ||
- | |||
- | ===== EFO wand height adjustment ===== | ||
- | |||
- | Vertical knob at top of bond head adjusts height. Knurled knob at left is lock. | ||
- | |||
- | FIXME: Target distance from capillary? | ||
- | ===== Wire feeding ===== | ||
- | |||
- | FIXME: Write this! |