 Above: front and rear of TCP-121 controller Above: front and rear of TCP-121 controller
  
-Many of the controllers can be used with various pumps but mind that the connector wiring can differ despite being the same connectors.+Many of the controllers can be used with various pumps but mind that the connector wiring can differ despite being the same connectors.  Some of the smaller controllers (ex: TCP-015) use a smaller power connector so look carefully when matching cables.
  
 +====== TCP121 ======
  
-====== Station controllers ======+Switches: 
 +  * S9 (left): standby (operate at 66% full speed) 
 +  * S2 (middle): heating, turbo pump 
 +  * S1 (right): power.  Reset by holding power off for 2 seconds
  
 +Connectors:
 +  * X1 (bottom circular): 
 +  * X2 (middle circular): 
 +  * X3 (top circular): 
 +  * X4 (right): 
 +  * X5 (left): turbo pump
  
-Above: +System connectors (referenced in schematics but not part of the TCP121 itself): 
 +  * X8: circular connector on the turbo pump, goes to X5 
 + 
 +Fuses: 
 +^ Fuse ^ Rating ^ Purpose ^ 
 +| F1 | 2.5A | Drive electronics | 
 +| F2 | 0.2A | Vent valve | 
 +| F3 | 2.5A | Heater | 
 +| F4 | 0.5A | Cooling | 
 + 
 + 
 +====== Station controllers ====== 
 + 
 +Above: TCP303
  
 There are also some accessories that allow monitoring pump coolant, controlling vent valves, and other things. There are also some accessories that allow monitoring pump coolant, controlling vent valves, and other things.
  
-====== Cables ====== 
  
 +====== Cabling ======
 +
 +===== Mains power =====
 +
 +==== Small plug (12 pin) ====
 +
 +{{:equipment:vacuum:balzers:mains_cable12:0.jpg?150|}}
 +
 +Above: A left, B right, 1 bottom, 6 top
 +
 +For TCP-040, TCP-300, & TCP-310 [WIRING: TCP-270]:
 +^ Purpose ^ Color ^ Pin ^
 +| Ground | green or green-yellow | A6 |
 +| Neutral | white or brown | A2 |
 +| Hot | black or blue | B1 |
 +
 +
 +==== Large plug (16 pin) ====
 +
 +Mains to X4 [TCP121 op inst, fig 10]:
 +
 +^ Purpose ^ Pin ^ 120V wire color ^
 +| Ground (PE / protective earth) | A8 | green |
 +| Neutral (N) | A2 | white |
 +| Hot (L / live) | B2 | black |
 +| Jumper | A1-B1 | N/A |
 +
 +Confirmed some of these by comparing schematics (which is somewhat hard to read) to pinout by pressing power switch
 +
 +
 +===== Controller to pump =====
 +
 +==== TCP120/121 to TPH/TPU 060, 240, 330 ====
 +
 +X5 (controller) to X8 (pump) [TCP121 op inst, fig 22].  Verified on "3m PM 011 232-X" cable
 +
 +^ Signal ^ TPU/TPH pump ^ TCP controller ^
 +|  | A | A5 |
 +|  | B | A4 |
 +|  | C | A3 |
 +|  | D | A2 |
 +|  | E | A1 |
 +|  | F | B6 |
 +|  | G | B5 |
 +|  | H | B4 |
 +|  | J | B3 |
 +|  | K | B2 |
 +|  | L | B1 |
 +|  | M | A6 |
 +|  | N | A7 |
 +|  | P | B7 |
 +|  | R | A1 |
 +|  | S | B8 |
 +|  | T | A2 |
 +|  | U | A3 |
 +|  | V | A8 |
 +
 +==== PM 441018-X ====
 +
 +Took the connector off of it to make above, pinned out by JM
  
 +| A | a5 |
 +| B | a4 |
 +| C | a3 |
 +| D | a2 |
 +| E | a1 |
 +| F | b6 |
 +| G | a5 |
 +| H | a4 |
 +| J | a3 |
 +| K | a2 |
 +| L | a1 |
 +| N | a6 |
 +| M | N/C |
 +| P | N/C |
 +| R | N/C |
 +| S | N/C |
 +| T | N/C |
 +| U | N/C |
 +| V | N/C |
  
 ====== History ====== ====== History ======
Line 49: Line 150:
   * Rebuild kits   * Rebuild kits
     * http://www.sisweb.com/vacuum/turbo-repair-kits.htm     * http://www.sisweb.com/vacuum/turbo-repair-kits.htm
 +  * WIRING: TCP-270: http://www.idealvac.com/files/images/Pfeiffer_TCP-270_versus_040_300_310_AC_Cable_Drawings.pdf
 +  * TCP120/121 Operating Instructions (TCP121 op inst)
  