Line 26: Line 26:
  
 ====== TCP121 ====== ====== TCP121 ======
 +
 +Switches:
 +  * S9 (left): standby (operate at 66% full speed)
 +  * S2 (middle): heating, turbo pump
 +  * S1 (right): power.  Reset by holding power off for 2 seconds
  
 Connectors: Connectors:
Line 43: Line 48:
 | F3 | 2.5A | Heater | | F3 | 2.5A | Heater |
 | F4 | 0.5A | Cooling | | F4 | 0.5A | Cooling |
 +
  
 ====== Station controllers ====== ====== Station controllers ======
  
- +Above: TCP303
-Above: +
  
 There are also some accessories that allow monitoring pump coolant, controlling vent valves, and other things. There are also some accessories that allow monitoring pump coolant, controlling vent valves, and other things.
Line 70: Line 75:
  
 ==== Large plug (16 pin) ==== ==== Large plug (16 pin) ====
- 
-XXX: diagram is a little iffy, probably disassemble to confirm this 
  
 Mains to X4 [TCP121 op inst, fig 10]: Mains to X4 [TCP121 op inst, fig 10]:
  
-^ Purpose ^ Pin ^ +^ Purpose ^ Pin ^ 120V wire color 
-| Ground | A8 | +| Ground (PE / protective earth) | A8 | green 
-| Neutral | A2 | +| Neutral (N) | A2 | white 
-| Hot | B2 | +| Hot (L / live) | B2 | black 
-| Jumper | A1-B1 |+| Jumper | A1-B1 | N/A | 
 + 
 +Confirmed some of these by comparing schematics (which is somewhat hard to read) to pinout by pressing power switch
  
  
Line 86: Line 91:
 ==== TCP120/121 to TPH/TPU 060, 240, 330 ==== ==== TCP120/121 to TPH/TPU 060, 240, 330 ====
  
-X5 (controller) to X8 (pump) [TCP121 op inst, fig 22]:+X5 (controller) to X8 (pump) [TCP121 op inst, fig 22].  Verified on "3m PM 011 232-X" cable
  
 ^ Signal ^ TPU/TPH pump ^ TCP controller ^ ^ Signal ^ TPU/TPH pump ^ TCP controller ^
-|  | B8 +|  | A5 
-|  | A8 +|  | A4 
-|  | B7 +|  | A3 
-|  | A7 |+|  | A2 | 
 +|  | E | A1 |
 |  | F | B6 | |  | F | B6 |
-|  | B1 |+|  | B5 |
 |  | H | B4 | |  | H | B4 |
-|  | M | A6 | 
 |  | J | B3 | |  | J | B3 |
 |  | K | B2 | |  | K | B2 |
-|  | B5 |+|  | B1 | 
 +|  | M | A6 | 
 +|  | N | A7 | 
 +|  | P | B7 |
 |  | R | A1 | |  | R | A1 |
-|  | A1 |+|  | B8 |
 |  | T | A2 | |  | T | A2 |
-|  | D | A2 | 
 |  | U | A3 | |  | U | A3 |
-|  | A3 +|  | A8 
-|  | B | A4 | + 
-|  | A | A5 |+==== PM 441018-X ==== 
 + 
 +Took the connector off of it to make above, pinned out by JM
  
 +| A | a5 |
 +| B | a4 |
 +| C | a3 |
 +| D | a2 |
 +| E | a1 |
 +| F | b6 |
 +| G | a5 |
 +| H | a4 |
 +| J | a3 |
 +| K | a2 |
 +| L | a1 |
 +| N | a6 |
 +| M | N/C |
 +| P | N/C |
 +| R | N/C |
 +| S | N/C |
 +| T | N/C |
 +| U | N/C |
 +| V | N/C |
  
 ====== History ====== ====== History ======