equipment:vacuum:balzers:turbo
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| equipment:vacuum:balzers:turbo [2013/08/11 02:11] – [TCP120/121 to TPH/TPU 060, 240, 330] mcmaster | equipment:vacuum:balzers:turbo [2025/08/04 21:23] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 91: | Line 91: | ||
| ==== TCP120/121 to TPH/TPU 060, 240, 330 ==== | ==== TCP120/121 to TPH/TPU 060, 240, 330 ==== | ||
| - | X5 (controller) to X8 (pump) [TCP121 op inst, fig 22]: | + | X5 (controller) to X8 (pump) [TCP121 op inst, fig 22]. Verified on "3m PM 011 232-X" cable |
| ^ Signal ^ TPU/TPH pump ^ TCP controller ^ | ^ Signal ^ TPU/TPH pump ^ TCP controller ^ | ||
| - | | | S | B8 | | + | | | A | A5 | |
| - | | | V | A8 | | + | | | B | A4 | |
| - | | | P | B7 | | + | | | C | A3 | |
| - | | | N | A7 | | + | | | D | A2 | |
| + | | | E | A1 | | ||
| | | F | B6 | | | | F | B6 | | ||
| - | | | L | B1 | | + | | | G | B5 | |
| | | H | B4 | | | | H | B4 | | ||
| - | | | M | A6 | | ||
| | | J | B3 | | | | J | B3 | | ||
| | | K | B2 | | | | K | B2 | | ||
| - | | | G | B5 | | + | | | L | B1 | |
| + | | | M | A6 | | ||
| + | | | N | A7 | | ||
| + | | | P | B7 | | ||
| | | R | A1 | | | | R | A1 | | ||
| - | | | E | A1 | | + | | | S | B8 | |
| | | T | A2 | | | | T | A2 | | ||
| - | | | D | A2 | | ||
| | | U | A3 | | | | U | A3 | | ||
| - | | | C | A3 | | + | | | V | A8 | |
| - | | | B | A4 | | + | |
| - | | | A | A5 | | + | |
| - | ==== Scrap cable ==== | + | ==== PM 441018-X |
| Took the connector off of it to make above, pinned out by JM | Took the connector off of it to make above, pinned out by JM | ||