User Tools

Site Tools


equipment:vacuum:fittings

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
equipment:vacuum:fittings [2013/11/23 05:23] mcmasterequipment:vacuum:fittings [2013/11/23 06:09] (current) mcmaster
Line 5: Line 5:
  
 ====== Connector comparison ====== ====== Connector comparison ======
 +
 +Swagelok tubing postfix codes [Vacuum Tubing Products]
 +
 +^ End Connection(s) ^ Designator ^
 +| VCR female one end only | FR |
 +| VCR female both ends | DFR |
 +| VCR female one end, VCR male other end  | FMR |
 +| VCR female one end, XBA adapter other end  | FRB |
 +| VCR male one end only  | MR |
 +| VCR male both ends | DMR |
 +| VCR male one end, XBA adapter other end | MRB |
 +| VCO female one end only | FO |
 +| VCO female both ends | DFO |
 +| VCO female one end, VCO male other end  | FMO |
 +| VCO female one end, XBA adapter other end  | FOB |
 +| VCO male one end only | MO |
 +| VCO male both ends | DMO |
 +| XBA adapter one end only | -B1 |
 +| XBA adapter both ends | -B2 |
 +
  
 ===== Installation ===== ===== Installation =====
Line 14: Line 34:
  
 My guess is that VCR fittings seal best.  Tube fittings probably seal pretty good the first time used but may lose their seal if not carefully re-installed. My guess is that VCR fittings seal best.  Tube fittings probably seal pretty good the first time used but may lose their seal if not carefully re-installed.
 +
 +VCO likely doesn't seal as well as VCR but probably worse than a properly installed tube fitting as well.
  
  
Line 19: Line 41:
  
 VCR gaskets should be used fresh for each install but you can probalby get away with reusing the same gasket a few times for most applications.  Swagelok tube fittings can be re-installed to the same location as long as they are installed in the same orientation.  However, to get a proper tube fitting seal on a new surface with used fittings I imagine you'd have to replace the ferrule which is probably more expensive and labor intensive than replacing a simple VCR gasket. VCR gaskets should be used fresh for each install but you can probalby get away with reusing the same gasket a few times for most applications.  Swagelok tube fittings can be re-installed to the same location as long as they are installed in the same orientation.  However, to get a proper tube fitting seal on a new surface with used fittings I imagine you'd have to replace the ferrule which is probably more expensive and labor intensive than replacing a simple VCR gasket.
 +
 +VCO gaskets/fittings can be reused many times.  Gaskets are inexpensive to replace if damaged.
 +
 +
 +===== Pressure =====
 +
 +Didn't see ratings specific to particular connector types.  However, [Vacuum Tubing Products]:
 +
 +  * "1/4 in. outside diameter tube—ultrahigh vacuum (10 –9 torr) to 100 psig (6.8 bar)
 +  * 3/8 in. through 1 1/2 in. outside diameter tube—ultrahigh vacuum (10 –9 torr) to 25 psig (1.7 bar)"
 +
 +
 +===== Temperature =====
 +
 +[Vacuum Tubing Products]:
 +
 +  * "VCR end connections—70 to 1000°F (20 to 537°C)
 +  * VCO end connections—70 to 400°F (20 to 204°C), based on standard fluorocarbon FKM O-ring material
 +  * XBA end connections—70 to 1000°F (20 to 537°C)
 +    * When used with Ultra-Torr fittings—70 to 400°F (20 to 204°C)"
 +
  
 ===== Custom builds ===== ===== Custom builds =====
Line 165: Line 208:
  
 Because of the gland nature it would seem hard to convert the more readily availble Swagelok tube adapters to VCR fittings without using a separate tube fitting to VCR adapter Because of the gland nature it would seem hard to convert the more readily availble Swagelok tube adapters to VCR fittings without using a separate tube fitting to VCR adapter
 +
 +Naming seems to follow MAT-OD-X-LENPFX
 +  * MAT: 321 for 321 stainless steel
 +  * OD: outer diamter of tubing as 16ths of an inch (4/16 = 1/4)
 +  * X: flexible convoluted tubing?
 +  * LEN: length in inches (which part exactly?)
 +  * PFX: postfix
 +
 +Naming  examples:
 +  * 321-4-X-2FR: 321 SS, 1/4" OD tubing,  with VCR female on one end
 +  * 321-4-X-2DFR for convoluted tubing with VCR female on both ends
  
  
equipment/vacuum/fittings.1385184212.txt.gz · Last modified: 2013/11/23 05:23 by mcmaster