equipment:vacuum:fittings
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
equipment:vacuum:fittings [2013/11/23 05:23] – mcmaster | equipment:vacuum:fittings [2013/11/23 06:09] (current) – mcmaster | ||
---|---|---|---|
Line 5: | Line 5: | ||
====== Connector comparison ====== | ====== Connector comparison ====== | ||
+ | |||
+ | Swagelok tubing postfix codes [Vacuum Tubing Products] | ||
+ | |||
+ | ^ End Connection(s) ^ Designator ^ | ||
+ | | VCR female one end only | FR | | ||
+ | | VCR female both ends | DFR | | ||
+ | | VCR female one end, VCR male other end | FMR | | ||
+ | | VCR female one end, XBA adapter other end | FRB | | ||
+ | | VCR male one end only | MR | | ||
+ | | VCR male both ends | DMR | | ||
+ | | VCR male one end, XBA adapter other end | MRB | | ||
+ | | VCO female one end only | FO | | ||
+ | | VCO female both ends | DFO | | ||
+ | | VCO female one end, VCO male other end | FMO | | ||
+ | | VCO female one end, XBA adapter other end | FOB | | ||
+ | | VCO male one end only | MO | | ||
+ | | VCO male both ends | DMO | | ||
+ | | XBA adapter one end only | -B1 | | ||
+ | | XBA adapter both ends | -B2 | | ||
+ | |||
===== Installation ===== | ===== Installation ===== | ||
Line 14: | Line 34: | ||
My guess is that VCR fittings seal best. Tube fittings probably seal pretty good the first time used but may lose their seal if not carefully re-installed. | My guess is that VCR fittings seal best. Tube fittings probably seal pretty good the first time used but may lose their seal if not carefully re-installed. | ||
+ | |||
+ | VCO likely doesn' | ||
Line 19: | Line 41: | ||
VCR gaskets should be used fresh for each install but you can probalby get away with reusing the same gasket a few times for most applications. | VCR gaskets should be used fresh for each install but you can probalby get away with reusing the same gasket a few times for most applications. | ||
+ | |||
+ | VCO gaskets/ | ||
+ | |||
+ | |||
+ | ===== Pressure ===== | ||
+ | |||
+ | Didn't see ratings specific to particular connector types. | ||
+ | |||
+ | * "1/4 in. outside diameter tube—ultrahigh vacuum (10 –9 torr) to 100 psig (6.8 bar) | ||
+ | * 3/8 in. through 1 1/2 in. outside diameter tube—ultrahigh vacuum (10 –9 torr) to 25 psig (1.7 bar)" | ||
+ | |||
+ | |||
+ | ===== Temperature ===== | ||
+ | |||
+ | [Vacuum Tubing Products]: | ||
+ | |||
+ | * "VCR end connections—70 to 1000°F (20 to 537°C) | ||
+ | * VCO end connections—70 to 400°F (20 to 204°C), based on standard fluorocarbon FKM O-ring material | ||
+ | * XBA end connections—70 to 1000°F (20 to 537°C) | ||
+ | * When used with Ultra-Torr fittings—70 to 400°F (20 to 204°C)" | ||
+ | |||
===== Custom builds ===== | ===== Custom builds ===== | ||
Line 165: | Line 208: | ||
Because of the gland nature it would seem hard to convert the more readily availble Swagelok tube adapters to VCR fittings without using a separate tube fitting to VCR adapter | Because of the gland nature it would seem hard to convert the more readily availble Swagelok tube adapters to VCR fittings without using a separate tube fitting to VCR adapter | ||
+ | |||
+ | Naming seems to follow MAT-OD-X-LENPFX | ||
+ | * MAT: 321 for 321 stainless steel | ||
+ | * OD: outer diamter of tubing as 16ths of an inch (4/16 = 1/4) | ||
+ | * X: flexible convoluted tubing? | ||
+ | * LEN: length in inches (which part exactly?) | ||
+ | * PFX: postfix | ||
+ | |||
+ | Naming | ||
+ | * 321-4-X-2FR: | ||
+ | * 321-4-X-2DFR for convoluted tubing with VCR female on both ends | ||
equipment/vacuum/fittings.1385184212.txt.gz · Last modified: 2013/11/23 05:23 by mcmaster