equipment:vacuum:gp:igc
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
equipment:vacuum:gp:igc [2013/08/17 22:55] – mcmaster | equipment:vacuum:gp:igc [2013/10/20 14:59] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 22: | Line 22: | ||
{{: | {{: | ||
+ | |||
+ | The DA-15 male-male connector between the two units is straight through. | ||
+ | |||
+ | "Degas can not be activated unless the IG pressure is below 5 x 10-5 in torr/mbar units, or 6.6 x 10-3 in pascal units." | ||
Line 45: | Line 49: | ||
^ Pin ^ Signal ^ Notes ^ | ^ Pin ^ Signal ^ Notes ^ | ||
- | | 1 | | | | + | | 1 | Anode grid | | |
- | | 2 | | | | + | | 2 | Filament |
- | | 3 (raised) | | | | + | | 3 (raised) | N/C | Structural: supports top of anode grid. Electrically disconnected at STP | |
- | | 4 | | | | + | | 4 | Filament |
- | | 5 | | | | + | | 5 | Anode grid | | |
===== Controller ===== | ===== Controller ===== | ||
Line 56: | Line 60: | ||
{{: | {{: | ||
+ | |||
+ | |||
+ | ===== Convectron tubes ===== | ||
+ | |||
+ | Looks like its designed for GP-275 tubes although the manual just says " | ||
+ | |||
+ | Seems that Duniway Stockroom Corp. CVT-275-101 is a third party alternative. | ||
+ | |||
====== References ====== | ====== References ====== |
equipment/vacuum/gp/igc.1376780132.txt.gz · Last modified: 2013/10/20 14:59 (external edit)