====== Pumps ====== {{:equipment:vacuum:balzers:tph_050:0.jpg?300|}} Above: TPH 050 TPH series pumps are ISO and/or KF inlet flanges. TPU series have conflat inlet flanges. I believe all have KF outlet flanges. I thought the second number is supposed to indicate L/S but my TPH 050 plate clearly lists 25 L/s. Smaller pumps (say < 50 L/s) tend to be passively cooled. Somewhat larger pumps can be air cooled but really large ones I think are only water cooled. In addition to the inlet and outlet flange, most (all?) of them also have a vent port. This is supposed to help in venting the chamber without venting through the foreline pump which could push contamination into the chamber. {{:equipment:vacuum:balzers:tph_050:connector.jpg?300|}} Above: male receptacle used on balzers turbo pumps ====== Pump controllers ====== {{:equipment:vacuum:balzers:tcp121:front.jpg?300|}} {{:equipment:vacuum:balzers:tcp121:back.jpg?300|}} Above: front and rear of TCP-121 controller Many of the controllers can be used with various pumps but mind that the connector wiring can differ despite being the same connectors. Some of the smaller controllers (ex: TCP-015) use a smaller power connector so look carefully when matching cables. ====== TCP121 ====== Switches: * S9 (left): standby (operate at 66% full speed) * S2 (middle): heating, turbo pump * S1 (right): power. Reset by holding power off for 2 seconds Connectors: * X1 (bottom circular): * X2 (middle circular): * X3 (top circular): * X4 (right): * X5 (left): turbo pump System connectors (referenced in schematics but not part of the TCP121 itself): * X8: circular connector on the turbo pump, goes to X5 Fuses: ^ Fuse ^ Rating ^ Purpose ^ | F1 | 2.5A | Drive electronics | | F2 | 0.2A | Vent valve | | F3 | 2.5A | Heater | | F4 | 0.5A | Cooling | ====== Station controllers ====== Above: TCP303 There are also some accessories that allow monitoring pump coolant, controlling vent valves, and other things. ====== Cabling ====== ===== Mains power ===== ==== Small plug (12 pin) ==== {{:equipment:vacuum:balzers:mains_cable12:0.jpg?150|}} Above: A left, B right, 1 bottom, 6 top For TCP-040, TCP-300, & TCP-310 [WIRING: TCP-270]: ^ Purpose ^ Color ^ Pin ^ | Ground | green or green-yellow | A6 | | Neutral | white or brown | A2 | | Hot | black or blue | B1 | ==== Large plug (16 pin) ==== Mains to X4 [TCP121 op inst, fig 10]: ^ Purpose ^ Pin ^ 120V wire color ^ | Ground (PE / protective earth) | A8 | green | | Neutral (N) | A2 | white | | Hot (L / live) | B2 | black | | Jumper | A1-B1 | N/A | Confirmed some of these by comparing schematics (which is somewhat hard to read) to pinout by pressing power switch ===== Controller to pump ===== ==== TCP120/121 to TPH/TPU 060, 240, 330 ==== X5 (controller) to X8 (pump) [TCP121 op inst, fig 22]. Verified on "3m PM 011 232-X" cable ^ Signal ^ TPU/TPH pump ^ TCP controller ^ | | A | A5 | | | B | A4 | | | C | A3 | | | D | A2 | | | E | A1 | | | F | B6 | | | G | B5 | | | H | B4 | | | J | B3 | | | K | B2 | | | L | B1 | | | M | A6 | | | N | A7 | | | P | B7 | | | R | A1 | | | S | B8 | | | T | A2 | | | U | A3 | | | V | A8 | ==== PM 441018-X ==== Took the connector off of it to make above, pinned out by JM | A | a5 | | B | a4 | | C | a3 | | D | a2 | | E | a1 | | F | b6 | | G | a5 | | H | a4 | | J | a3 | | K | a2 | | L | a1 | | N | a6 | | M | N/C | | P | N/C | | R | N/C | | S | N/C | | T | N/C | | U | N/C | | V | N/C | ====== History ====== "1967 Pfeiffer was acquired by Balzers AG of Liechtenstein. 1996 Pfeiffer Vacuum Technology AG is now an independent Company operating worldwide and the first medium-sized German company..." [Compound semi] ====== References ====== * Compound semi: http://www.compoundsemiconductor.net/csc/company-details.php?cid=8266 * Ideal vacuum products manuals: http://www.pchemlabs.com/manuals.asp * Pump/controller compatibility chart: http://www.hsdengineering.com/images/pfeiffer_table.pdf * Rebuild kits * http://www.sisweb.com/vacuum/turbo-repair-kits.htm * WIRING: TCP-270: http://www.idealvac.com/files/images/Pfeiffer_TCP-270_versus_040_300_310_AC_Cable_Drawings.pdf * TCP120/121 Operating Instructions (TCP121 op inst)