User Tools

Site Tools


equipment:chiller

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
equipment:chiller [2018/12/01 05:33] mcmasterequipment:chiller [2018/12/01 05:52] (current) – [TEC misc] mcmaster
Line 1: Line 1:
 mcmaster equipment notes. Both broken when I got them mcmaster equipment notes. Both broken when I got them
 +
 +
 +====== TEC misc ======
 +
 +Failure modes?
 +
 +Can they fail open? Maybe not (assuming the wires are good). I think all of the elements are in parallel
 +
 +https://electronics.stackexchange.com/questions/261655/what-happens-when-a-peltier-fails
 +
 +Firstly, it appears that peltiers often slowly decline according to the referenced article, with increased resistance and decreased heat pump capacity.
 +
 +Therefore, my proposition is that in a typical heating application the heat produced by a perfeclty-shorted 100W peltier would be the equivalent of a 50W, poorly back-insulted, resistance element.
  
  
Line 5: Line 18:
  
 Power supply: roughly 12V @ 8A. Power supply: roughly 12V @ 8A.
 +
 +TODO:
 +  * Try cooling using external pump + power supply
  
  
Line 17: Line 33:
  
 Measured one TEC: 4V @ 1.4A start voltage Measured one TEC: 4V @ 1.4A start voltage
 +
 +TODO:
 +  * Verify expected resistance (10 * 2.4 ohm => 24 ohm)
 +  * Try cooling using external power supply + pump
 +  * Backup PIC firmware?
 +    * Might also be useful to figure out serial protocol
  
 ===== mcmaster ===== ===== mcmaster =====
Line 34: Line 56:
 - + - +
 </code> </code>
 +
 +I found DT12-4 and DT12-8 datasheets. Looks like linear relationship. Interpolated datasheet:
 +  * dtmax: 66 (27C), 74 (50C) C
 +  * Qmax: 54 (27C), 58 (50C) W
 +  * Imax: 5.55 A
 +  * VMax: 14.7 to 16.4 V
 +  * AC resistance: 2.4 ohm
 +
  
 ===== Thread ===== ===== Thread =====
equipment/chiller.1543642395.txt.gz · Last modified: 2018/12/01 05:33 by mcmaster