- | ====== Long working distance (" | ||
- | These are the objectives people usually refer to. Edmund Optics seems to be the official distributor although I'm not sure they carry all types such as the BD Plan. | ||
- | |||
- | ===== M Plan Apo ===== | ||
- | |||
- | Wavelength correction: 436 nm - 656 nm | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ EO list price ^ | ||
- | | [[M Plan Apo 1X]] | 0.025 | 11.0 | 200 | 11.0 | 440 | N/A | | ||
- | | [[M Plan Apo 2X]] | 0.055 | 34.0 | 100 | 5.0 | 91 | 869 | | ||
- | | [[M Plan Apo 5X]] | 0.14 | 34.0 | 40 | 2.0 | 14 | 650 | | ||
- | | [[M Plan Apo 7.5X]] | 0.21 | 35.0 | 26.67 | 1.3 | 6.2 | 1220 | | ||
- | | [[M Plan Apo 10X]] | 0.28 | 34.0 | 20 | 1.0 | 3.5 | 819 | | ||
- | | [[M Plan Apo 20X]] | 0.42 | 20.0 | 10 | 0.7 | 1.6 | 1899 | | ||
- | | [[M Plan Apo 50X]] | 0.55 | 13.0 | 4 | 0.5 | 0.9 | 2490 | | ||
- | | [[M Plan Apo 100X]] | 0.70 | 6.0 | 2 | 0.4 | 0.6 | 3190 | | ||
- | |||
- | ===== M Plan Apo High Resolution (HR) ===== | ||
- | |||
- | Wavelength correction: 436 - 656 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ EO list price ^ | ||
- | | [[M Plan Apo HR 10X]] | 0.42 | 15.0 | 20 | 0.6 | 1.55 | 7210 | | ||
- | | [[M Plan Apo HR 50X]] | 0.75 | 5.2 | 4 | 0.4 | 0.48 | 5290 | | ||
- | | [[M Plan Apo HR 100X]] | 0.90 | 1.3 | 2 | 0.3 | 0.34 | 5690 | | ||
- | |||
- | ===== M Plan Apo Super Long (SL) working distance ===== | ||
- | |||
- | Wavelength correction: 436 - 656 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ ^ EO list price ^ | ||
- | | [[M Plan Apo SL20x]] | 0.28 | 30.5 | 10 | 1.0 | 3.5 | 2899 | | ||
- | | [[M Plan Apo SL50x]] | 0.42 | 20.5 | 4 | 0.7 | 1.6 | 3050 | | ||
- | | [[M Plan Apo SL80x]] | 0.50 | 15.0 | 2.5 | 0.6 | 1.1 | 3750 | | ||
- | | [[M Plan Apo SL100x]] | 0.55 | 13.0 | 2 | 0.5 | 0.9 | 4500 | | ||
- | | [[M Plan Apo SL200x]] | 0.62 | 13.0 | 1 | 0.4 | 0.7 | 9930 | | ||
- | |||
- | |||
- | ===== G Plan Apo ===== | ||
- | |||
- | Wavelength correction: 436 - 656 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[G Plan Apo 20x]] | 0.28 | 29.42 "in air" | 10 | 1.0 | 3.5 | | ||
- | | [[G Plan Apo 50x]] | 0.50 | 13.89 "in air" | 4 | 0.6 | 1.1 | | ||
- | |||
- | ===== M Plan Apo NIR ===== | ||
- | |||
- | Wavelength correction: 480 - 1800 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[M Plan Apo NIR 5x]] | 0.14 | 37.5 | 40 | 2.0 | 14.0 | | ||
- | | [[M Plan Apo NIR 10x]] | 0.26 | 30.5 | 20 | 1.1 | 4.1 | | ||
- | | [[M Plan Apo NIR 20x]] | 0.40 | 20.0 | 10 | 0.7 | 1.7 | | ||
- | | [[M Plan Apo NIR 50x]] | 0.42 | 17.0 | 4 | 0.7 | 1.6 | | ||
- | | [[M Plan Apo NIR 100x]] | 0.50 | 12.0 | 2 | 0.6 | 1.1 | | ||
- | |||
- | ===== M Plan Apo NIR-HR ===== | ||
- | |||
- | Wavelength correction: 480 - 1800 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[M Plan Apo NIR-HR 50x]] | 0.65 | 10.0 | 4 | 0.42 | 0.65 | | ||
- | | [[M Plan Apo NIR-HR 100x]] | 0.70 | 10.0 | 2 | 0.39 | 0.56 | | ||
- | |||
- | ===== LCD Plan Apo NIR ===== | ||
- | |||
- | Wavelength correction: 480 - 1800 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[LCD Plan Apo NIR 20x(t1.1)]] | 0.40 | 19.98 "in air" | 10 | 0.7 | 1.7 | | ||
- | | [[LCD Plan Apo NIR 50x(t1.1)]] | 0.42 | 17.13 "in air" | 3.9 | 0.7 | 1.6 | | ||
- | | [[LCD Plan Apo NIR 50x(t0.7)]] | 0.42 | 17.26 "in air" | 3.9 | 0.7 | 1.6 | | ||
- | | [[LCD Plan Apo NIR 100x(t0.7)]] | 0.50 | 12.11 "in air" | 2 | 0.6 | 1.1 | | ||
- | |||
- | ===== M Plan Apo NUV ===== | ||
- | |||
- | Wavelength correction: 355 - 620 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[LCD Plan Apo NUV 20x]] | 0.40 | 17.0 | 10 | 0.7 | 1.7 | | ||
- | | [[LCD Plan Apo NUV 50x]] | 0.42 | 15.0 | 4 | 0.7 | 1.6 | | ||
- | | [[LCD Plan Apo NUV 100x]] | 0.50 | 11.0 | 2 | 0.6 | 1.1 | | ||
- | |||
- | ===== LCD Plan Apo NUV ===== | ||
- | |||
- | Wavelength correction: 355 - 620 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[LCD Plan Apo NUV 50x(t0.7)]] | 0.42 | 14.76 "in air" | 4 | 0.7 | 1.6 | | ||
- | | [[LCD Plan Apo NUV 50x(t1.1)]] | 0.42 | 14.75 "in air" | 4 | 0.7 | 1.6 | | ||
- | |||
- | ===== M Plan UV ===== | ||
- | |||
- | Wavelength correction: 266, 550 | ||
- | |||
- | The important thing to know about these is that if you drop one on your foot you'll be balancing the hospital bill against the optics damage. | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm @ 266 nm ^ f mm @ 550 nm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[M Plan UV 20x]] | 0.36 | 15.0 | 10 | 10.4 | 0.8 | 2.1 | | ||
- | | [[M Plan UV 50x]] | 0.40 | 12.0 | 4 | 4.5 | 0.7 | 1.7 | | ||
- | | [[M Plan UV 80x]] | 0.55 | 10.0 | 2.5 | 2.9 | 0.5 | 0.9 | | ||
- | |||
- | ===== BD Plan Apo ===== | ||
- | |||
- | Wavelength correction: 436-656 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[BD Plan Apo 2x]] | 0.055 | 34.0 | 100 | 5.0 | 91 | | ||
- | | [[BD Plan Apo 5x]] | 0.14 | 34.0 | 40 | 2.0 | 14 | | ||
- | | [[BD Plan Apo 10x]] | 0.28 | 34.0 | 20 | 1.0 | 3.5 | | ||
- | | [[BD Plan Apo 20x]] | 0.42 | 20.0 | 10 | 0.7 | 1.6 | | ||
- | | [[BD Plan Apo 50x]] | 0.55 | 13.0 | 4 | 0.5 | 0.9 | | ||
- | | [[BD Plan Apo 100x]] | 0.70 | 6.0 | 2 | 0.4 | 0.6 | | ||
- | |||
- | |||
- | ===== BD Plan Apo HR ===== | ||
- | |||
- | Wavelength correction: 436-656 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[BD Plan Apo HR 50x]] | 0.75 | 5.2 | 4 | 0.4 | 0.48 | | ||
- | | [[BD Plan Apo HR 100x]] | 0.90 | 1.3 | 2 | 0.3 | 0.24 | | ||
- | |||
- | ===== BD Plan Apo SL ===== | ||
- | |||
- | Wavelength correction: 436-656 | ||
- | |||
- | ^ Model ^ Numerical Aperature (NA) ^ Working distance (WD) mm ^ Focal length f mm ^ Resolving power R um ^ Depth of focus +/- DF um ^ | ||
- | | [[BD Plan Apo SL20x]] | 0.28 | 30.5 | 10 | 1.0 | 3.5 | | ||
- | | [[BD Plan Apo SL50x]] | 0.42 | 20 | 4 | 0.7 | 1.6 | | ||
- | | [[BD Plan Apo SL80x]] | 0.50 | 13 | 2 | 0.6 | 1.1 | | ||
- | | [[BD Plan Apo SL100x]] | 0.55 | 13 | 2 | 0.5 | 0.9 | | ||
- | |||
- | ====== QV ====== | ||
- | |||
- | For machine inspection. | ||
- | |||
- | |||
- | ====== Misc ====== | ||
- | |||
- | They do seem to make a few " | ||
- | |||
- | Includes: | ||
- | * M50 | ||
- | |||
- | |||
- | ====== References ====== | ||
- | |||
- | 2012 prices are from EO website on Feb 26, 2012 | ||
- | |||
- | - "Long working distance objectives" | ||
- | - Edmund optics: Mitutoyo infinity corrected long working distance objectives: http:// | ||
- | - Edmund optics: Mitutoyo NIR, NUV, UV: infinity corrected objectives: http:// |