This is an old revision of the document!
Table of Contents
Useful for finding die position in packages, looking into epoxied modules, etc
Intensifying screens
Introduction to screens (ref):
- standard
- slow
- calcium tungstate
- rare earth
- fast
- gadolinium or lanthanum
- Commercial brands: Kodak Lanex
There's a good vendor summary / cross reference chart here: http://www.mcio.com/Products/comparison-chart.aspx
I think the number following the name is generally the gain. That is a 400 screen will put out twice as much light per x-ray as a 200 screen They call this the “speed” presumably because it makes film expose faster. Chart here
Brands:
- 3M
- AGFA
- DUPONT/STERLING
- FUJI
- JPI
- KIRAN
- KODAK
- Lanex: rare earth green
- KONICA
- MCI OPTONIX
Following sections are for screens I own. Basically they were cheap on eBay
Intensifying tube
was offered a broken tube but I don't think it would have been useful
DIY x-ray setups
Ben K x-ray, CBCT “chicken” setup
- originally unshielded but I think is now?
- In CBCT mode runs automatically via arduino and thus person doesn't have to get exposed
Russian fellow: http://habrahabr.ru/post/254015/
- …who gave himself acute radiation sickness. A stern warning to those not taking such a setup seriously
John M dental x-ray setup
- which has about 100 lbs of lead shielding
- also operated remotely via ssh to laptop
Rotary stage replacement
Goal: stop using my Sherline rotary stage and instead use spare CNC rotary stage (from laser machine purchase lot)
Motor: Vexta PH566-B 5 phase stepper
Controller: Rorze RD-053MS
- Has a lot of pins labeled
- Enclosed in box with cable running to the rotary table
- 3 per box
- Need to interface to output Centronix connector
The left side connections are pretty obvious:
- power
- 18V to 40VDC
- motor phases
Left side less so
- diff1
- diff2
- 4P IN
- FREE
- PHASE OUT
- ALARM OUT
Summary
- Up to 400 microsteps/step
- Current driven…looks like approx. 3.8mA at 5VDC?
- 3.3V compatible?
Two ways that step/direction can be configured
Two Clock Input (2CK) (Inputs two clock pulses - CW clock pulse and CCW clock pulse)
- CW+/-: Motor rotates in CW direction with a pulse current of 8 to 20mA from CW+ to CW- terminal.
- CCW+/-: Motor rotates in CCW direction with a pulse current of 8 to 20mA from CCW+ to CCW- terminal.
One Clock Input (1CK) (Inputs clock pulse and direction (CW, CCW))
- CLK+/-: Motor rotates in CW direction with a pulse current of 8 to 20mA from CLK+ to CLK- terminal and UD input off.
- UD+/-: Motor rotates in CCW direction with a pulse current of 8 to 20mA from CLK+ to CLK- terminal and UD input turned ON.
Basically it looks like second is standard step/direction configuration
- Yep buried in later documentation: Selects clock input, Two clock input method (2CK) or Pulse & Direction input method (1CK).
6-2 Full Step Input (4P IN +/-): Motor rotates in full step mode with a pulse current of 2 to 10mA (approx. 3.8mA at 5VDC) from “4P IN +” to “4P IN –”
6-3 Free Input (FREE +/-): The excitation current of motor will become 0 and a motor can be rotated by hand with a pulse current of 2 to 10mA (approx. 3.8mA at 5VDC) from “FREE+” to “FREE-”.
- NOTE: Do not turn this input ON when motor is running at high speed, this operation would
damage the amplifier circuits.
6-4 Phase Output (PHASE OUT+/-): PHASE OUT output (open collector output) is turned ON at the phase home. One pulse is put out every time the motor moves 7.2゚ in case of 0.72゚ motor. The Duty of output ON is 10%.
6-5 Alarm Output (ALARM OUT+/-): Overheating protection circuit intervenes turning ALARM output ON. (Open collector output ON)
All channels as given are configured the same
- 8-1 current range: 1.5A
- 8-2 clock select: 1 clock
- 8-3 auto current down: on
- 8-4:8-8: microstepping: 32
- D1: 0
- D2: 1
- D3: 0
- D4: 0
- D5: 1
- 1: to the left, 0: to the right (assuming OFF ⇒ 0)
Agilent PS test on CLK input while off (assuming its just a PD)
- 0V 3 mA (subtracted from all other values)
- 3.3V: 7 mA
- 5V: 13 mA
- They said 3.8 mA…are inputs non-uniform?
- 2 mA: 1.8 V
- 8 mA: 3.5 V
- 10 mA: 4.1 V
- 20 mA: 6.8 V
(note to self: script a curve tracer…)